G E T T I N G S T A R T E D
15
Zero-Span Toolbar 3.4
The zero-span toolbar is visible when the device is operatoring in zero-span mode. The toolbar is located
below the file menu and contains controls for maniputing the displays and controlling acquisitions.
Demod Selection The drop-down combo box allows you to select which type of
demodulation to perform and display. You may perform amplitude, frequency, or phase
demodulation on the IQ captures. The top zero-span plot will display the modulation and
allow the placement of markers and delta markers on the demodulated signal.
Marker Off Disables an active marker on the waveform.
Marker Delta Toggles the delta marker on the waveform.
Single Request the software to perform a capture and pause the display. The software
will continue to to update until the capture is triggered.
Auto Request the software continuously update with the specified trigger.
Preset Perform a hardware and software reset.
The Menu 3.5
File Menu 3.5.1
Print Print the current graticule view. The resulting print will not include the control
panel or the menu/toolbars.
Save as .bmp Save the current graticule view as a bitmap image.
Print Preview Shows you what will be printed using the print menu option.
ExportTrace CSV Saves the current visible trace as a CSV file.
Import Path Loss Import Path Loss Table This menu option allows you to
introduce path loss corrections for the incoming traces. See Additional Features:
Importing Path Loss and Limit Line Tables for more information.
Import Path Loss Clear Path Loss Table Remove any active
Import Limit Lines Import Limit Line Table Import a set of limit lines which
then the incoming trace is tested against. Limit lines are two lines across the span which
defines an acceptable amplitude region for a trace. You can specify a maximum limit or a
maximum and minimum set. See Additional Features: Importing Path Loss and Limit
Line Tables for more information.
Import Limit Lines Clear Limit Line Table Remove the active limit line traces.
Connect Device If no device is connected, this option will attempt to connect to the
first BB60 device found.
Disconnect Device This option disconnects the currently connected BB60 device. This
option combined with “Connect Device” is useful for cycling a devices power or swapping
devices without closing the Signal Hound software.
Exit Disconnect the device and close the software.

Table of Contents

Other manuals for Signal Hound BB60C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Signal Hound BB60C and is the answer not in the manual?

Signal Hound BB60C Specifications

General IconGeneral
BrandSignal Hound
ModelBB60C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals