StreamCaster MIMO Radio User Manual 3/17/15
10017C000 Silvus Technologies Confidential Page
5.1.5 Node Diagnostics
Figure 15 Node Diagnostics Configuration Page
The Node Diagnostics page allows the user to specify an IP and Port number for Temperature
and RSSI (Receiver Signal Strength Indication) reports to be delivered to. This is useful for users
that intend to feed this information into some other platform for analysis and recording. Section 7
gives more information on the format of streaming reports.
Additionally, this page allows the user to disable or enable the LED on the faceplate of the radio.
Temperature Thresholds:
In addition to receiving temperature reports, this page can be used to set minimum and maximum
temperature thresholds for the radio. The StreamCasterâ„¢ family of radios is equipped with on
board temperature sensors which are monitored to prevent overheating. Once a radio reaches the
maximum temperature threshold, the radio will begin to reduce its transmission time until the
temperature falls below the minimum temperature threshold. By default, the min and max values
are 75C and 85C respectively.