DL100 Series Universal Low-Power Inverter
32 Detailed Description of Functions
frequency should be appropriately reduced to improve the thermal characteristics
of the inverter.
It is used to set some characteristics related to the carrier (digital binary setting),
generally without modification.
LED unitsLoad-related adjustment
When this function is valid, when the load current is too large, in order to
ensure the safe operation of the inverter, the carrier will be automatically reduced.
LED ten digits: reserved
Hundreds of LEDs: reserved
Thousands of LEDs: reserved
Modify the parameters of the inverter to factory values.
0No action
1Standardized initializationRestore all parameters to factory settings
2Clear fault record
3 Fully initialized(restore all parameters to factory settings and clear fault
records)
This parameter is only valid when the frequency input channel selection
combination is set ([F0.00]=5)
The set frequency of the inverter is determined by the linear combination of
multiple frequency input channels. The set combination mode is shown in the
table below. Through the combination setting, multiple channels can jointly
control the frequency output of the inverter.
F0.10 Parameter initialization Predetermined area
0 ~ 10
F0.12 Frequency input channel combination Setting range: 0~11
F0.09 Carrier characteristics Predetermined area
0000 ~ 0001