EasyManua.ls Logo

Simrad CX34 - Page 175

Simrad CX34
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GOTO
t SimNet diagnostic
PLOT
Example:
CX44/54
Alarm:
Output (pin 1,2): ON
Alarm stand-by level: LOW
Pos-status:
Output (pin 4,6): ON
Pos-status stand-by level: HIGH
Log:
Output (pin 5,6): ON
MOB-input:
(pin 3,6)
Long press (5 sec.): EXTERNAL MOB
Short press: OFF
MENU
Exit Accept
ENT
Alarm
Setup menu Chapter 9-21
MOB-input
Press the external switch for more than 5 seconds to activate the
MOB function (fixed setting), and press the [ENT] key to start MOB
navigation.
Short press on the external switch (less than 5 seconds) will shift
page or plot ships position. Use the +/- keys to toggle between OFF,
SHIFT PAGE and PLOT SHIP’s POS:
SHIFT PAGE - short press on the external switch will shift to next
page stored under the PAGE key.
PLOT SHIP’s POS - short press on the external switch will plot and
save the actual position, which will be registered in the WP list.
CX34/44/54 Operator manual

Table of Contents

Related product manuals