© Mar. 2022 3-2 1323RD&1623RD Operation Manual
SAFETY
ELECTROCUTION
HAZARDS
NOTE: This machine is not insulated and does not have
an electric shock protection function.
All operators and managers shall comply with national
or local regulations regarding the minimum safe dis-
tance of live conductors above the ground. In the ab-
sence of such requirements, operators and managers
should follow the minimum safety distance require-
ments in Table 3-1 Minimum Safe Distance, page 3-
2.
ELECTRICAL SHOCK HAZARDS
Always maintain a safe distance
from power lines and electrical
equipment in accordance with ap-
plicable government regulations
and see Table 3-1 Minimum Safe
Distance, page 3-2.
Consider platform movement,
wire swinging or drooping, be-
ware of strong winds or gusts,
and do not operate the machine
when there is lightning or heavy
rain.
If the machine comes into contact
with live wires, keep away from
the machine. Personnel on the
ground or on the platform must
not touch or operate the machine
until the power is switched off.
Do not use the machine as a
ground wire during welding and
polishing operations.
Table 3-1 Minimum Safe Distance
Voltage
(Phase to Phase, kV)
Minimum Safe Distance
(m/ft)
0-50 3.05 (10)
50-200 4.60 (15)
200-350 6.10 (20)
350 -500 7.62 (25)
500 -750 10.67 (35)
750 -1000 13.725 (45)
TIPPING HAZARDS AND
RATED LOAD
Maximum platform capacity:
Table 3-2
1323RD
Platform retracted 680 kg (1499 lb)
Platform extended-extension
platform only (single)
227 kg (500 lb)
1623RD
Platform retracted 680 kg (1499 lb)
Platform extended-extension
platform only (single)
227 kg (500 lb)