PRE-OPERATION FUNCTION TEST
1323RD&1623RD Operation Manual 6-5 © Mar. 2022
EMERGENCY LOWERING
After pressing the emergency lowering combination
buttons, the platform can be lowered, even though
the engine is not started.
REGENERATION FUNCTION
1. Run the engine at low idle speed until the coolant
temperature reaches 60℃.
2. Move the regen interlock switch (toggle switch)
upward.
3. Press and hold the regen request switch (self-
reset switch) for 10s, and the regen execution
indicator light at the hour meter shall be lit at this
time.
4. Release the regen request switch for 3s, and the
regen request indicator light and the regen
execution indicator light on the hour meter shall
be lit and flashing respectively at this time.
5. Press and hold the regen request switch for 3s. At
this time, the high exhaust temperature indicator
light and regen execution indicator light at the
hour meter shall be on and lit respectively, the idle
speed of the engine shall be increased
automatically and the regeneration function shall
be performed.
• When performing the regeneration function, other
actions cannot be performed simultaneously.
After the operation is completed, move the regen
interlock switch downward to turn off the
regeneration function, or wait for 30mins to exit
the state automatically.
• Normally, 50 hours after the regeneration
operation, the regeneration can be performed
again. In case of a regeneration alarm, the
regeneration function will not be subject to the
restriction.
TESTING THE GROUND
CONTROLLER (SINOBOOM
CONTROL SYSTEM)
NOTICE
All tests on the ground controller shall be completed
within one cycle.