PRE-OPERATION FUNCTION TEST
1323RD&1623RD Operation Manual 6-19 © Mar. 2022
Table 6-7
Mdoels Test Results
1323RD
When the weight does not exceed 680 kg (1499 lb), ensure that the platform is able to rise to the
highest position.
When the platform load is greater than or equal to 816 kg (1799 lb), the platform lifting height
should be no greater than 3.2±0.5m (10ft 6in±1ft 8in).
1623RD
When the weight does not exceed 680 kg (1499 lb), ensure that the platform is able to rise to the
highest position.
When the platform load is greater than or equal to 816 kg (1799 lb), the platform lifting height
should be no greater than 3.2±0.5m (10ft 6in±1ft 8in).
NOTICE
When the temperature of hydraulic oil is low, the viscosity will increase, which will have a significant impact on the
pressure detection. If the environmental temperature difference between the place of the end customer of the
machine and the place of machine manufacturer factory is ≧10℃ (50°F), or if the hydraulic oil temperature is lower
than 15℃ (59°F), an alarm failure will occur when the rated load is lower than the standard rated load (the "OL"
symbol appears on the platform controller screen or the ground controller screen), please re-calibrate the weighing
sensor.