Control unit
Interval time, adjustable
(see "Mode of operation")
Contact time (pump cycle
time), adjustable
(see "Mode of operation")
Operation hour meter
Fault hour meter
Monitoring of external cycle
switches, adjustable
Modes of operation
IG502-2-I with control unit and screen
0.1…99.9 / 1...999 h / pulses (timer/counter mode)
Factory setting: tPA = 10 h
0.1 ... 99.9 min
KFA…W.. designs: min 0.6 min
Factory setting:tCO = 2.0 min
0.1 ... 99999.9 h (not deletable)
Factory setting: 0.0 h
0.1 ... 99999.9 h (not deletable)
Factory setting: 0.0 h
COP = CS (monitoring is active)
COP = OFF (monitoring is inactive)
Factory setting: COP = OFF
Counter or timer mode
Factory setting: Timer operation
1)
With NGLI Grade 2 grease, back pressure p = 50 bar and ambient temperature T = 20 °C, depends on pump element (see Table in Chapter 3.2, "Pump elements")
2)
With max. operating pressure p = 300 bar and ambient temperature T = 20°C