EasyManuals Logo

SKF KFG Series User Manual

SKF KFG Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Page 11
EN
1.7 Explosion protection information
Danger!
Only the pump models tested and
approved by SKF Lubrication Systems
Germany GmbH in accordance with
-
ted to be used in areas with explosion
protection. The relevant class of protec-
tion is engraved on the pump's rating
plate.

sure the lubricant is clean. The reservoir




-

potentially explosive atmosphere exists.

amount of lubricant must be removed.
Make sure there is no potentially explosive
atmosphere when doing this.

monitor must be supplied by an intrinsi-
cally safe circuit, e.g., through the installa-

by the customer.
The unit must be grounded via a ground
connection. The customer must install ad-
equate overload protection for the power
consumption of the motor.
To avoid electrostatic discharge, lay
hydraulic connecting lines in corrosion-
resistant metal tubing, e.g., stainless steel
pipe.
When setting up the pump, make sure the
setup location is level and not subject to
vibrations or jolts.
During maintenance work, use only tools
intended for use in potentially explosive
spaces or else make certain that there is
no potentially explosive atmosphere
present.
The service life of the oil lubrication pump
is limited. It must therefore undergo a
function and leak test at regular intervals.
Perform appropriate repairs in the event
of malfunctions, leaks, or rust. Replace the
pump if necessary.
The user must make sure through the
choice of the lubricant to be delivered that
no chemical reactions capable of serving
as ignition sources will occur in conjunc-
tion with the explosive atmospheres
expected.
The lubricant’s ignition temperature must
be at least 50 kelvin above the pumps
maximum surface temperature (tempera-
ture class).
Depending on the model design, the product
may be available in an explosion-proof design.
Assembly instructions
KFGS
KFG
KFGC

Other manuals for SKF KFG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF KFG Series and is the answer not in the manual?

SKF KFG Series Specifications

General IconGeneral
BrandSKF
ModelKFG Series
CategoryWater Pump
LanguageEnglish

Related product manuals