Page 75
EN
11.1 Timer operation
The interval and pump cycle are
time-dependent.
The lubrication cycle is controlled by the
pre-set, time-dependent values for PAUSE
and CONTACT.
PAUSE: Values in hours
CONTACT: Values in minutes
Set tPA and tCO in programming mode.
11. KFGS operating modes
11.2 Counter operation
The interval depends on the number of pulses;
the pump cycle time is time-dependent.
An external pulse generator must be attached
as described in Chapter 6.
PAUSE: Values in pulses
CONTACT: Values in minutes
A switch opens and closes based on machine
movements, revolutions, etc.
A lubrication is triggered once the set number
of pulses cPA is reached.
Set cPA and tCO in programming mode.
11.3 No system monitoring
In this operating mode, the lubrication cycle
is controlled solely by the pre-set values for
PAUSE and CONTACT.
Monitoring must be switched off. COP
= OFF System malfunctions are not
automatically detected or displayed.
11.4 With system monitoring
In this operating mode, system functions are
additionally monitored using external switches.
The following can be monitored:
Fill level in the lubricant reservoir
Function of progressive feeder using a
piston detector
Function of single-line system using a
pressure switch
Operational malfunctions are automati-
cally detected and displayed.
Monitoring is switched on.
COP = CS (PS not permitted on
progressive systems)
11. KFGS operating modes
KFGS

Other manuals for SKF KFG Series