Page 89
EN
KFGC (CAN bus) fault notifications
Fault Category Possible cause Rectification
Fill level warning Warning
Fill level in the lubricant reservoir
falls to warning sensor
Break in sensor cable
• Promptly refill with lubricant.
(see assembly instructions, Chapter 4.4.1, page 21)
• Replace cable.
Fill level fault Malfunction
Fill level in lubricant reservoir reaches
Break in sensor cable
• Immediately refill with lubricant
(see assembly instructions, Chapter 4.4.1, page 21).
• Replace the cable.
Cycle fault Malfunction
Lubrication line defective
Progressive feeder blocked or
defective
Piston detector defective
Insufficient lubricant
Break in sensor cable
• Replace the defective line.
• Clean the feeder or replace it.
• Replace the piston detector.
• Immediately refill with lubricant
(see Chapter 4.4.1, page 21),
change pump element if necessary.
• Replace the cable.
Pressure build-up
fault
Malfunction
Lubrication line defective
Pressure switch defective
Pressure relief valve blocked or
defective
Insufficient lubricant
Break in sensor cable
• Replace the defective line.
• Replace the pressure switch.
• Clean the valve or replace it.
• Immediately refill with lubricant
(see Chapter 4.4.1, page 21).
Replace the pump element if necessary
• Replace the cable.
Pressure reduction
fault
Malfunction
Pressure relief valve blocked or
defective
Pressure switch defective
Break in sensor cable
Lubricant too consistent
• Clean the valve or replace it.
• Replace the pressure switch.
• Replace the cable.
• Fill lubricant at suitable flow pressure, clean system.
14.2.7 Warning and malfunction indicator on KFGC (CAN bus) pump unit
14. Operational and pump faults
KFGC