Section 5 – Operation MEWP shutdown
5.9 MEWP shutdown
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
1. Select a reasonably well-protected location to
park the MEWP. This location must have a rm,
level surface, clear of obstructions, and trafc.
2. Fully lower the platform.
3. Push the emergency-stop button.
WARNING
Fall Hazard. Use the three points of contact
principle when you use the MEWP to enter or exit
the platform. If you do not obey, there is a risk of
death or serious injury.
4. Exit the platform.
5. Turn the off/platform/base key switch to the
off position on the base control console and
remove the key.
6. Push the emergency-stop button.
7. Turn the main power disconnect switch to the
off position.

Table of Contents

Other manuals for Skyjack SJ12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ12 and is the answer not in the manual?

Skyjack SJ12 Specifications

General IconGeneral
Gradeability25%
Drive Motor24V DC
Machine Width32 in (0.81 m)
Stowed Height6.5 ft
Overall Width32 in (0.81 m)
Stowed Height (Rails Folded)6.5 ft
Drive Speed (Elevated)0.5 mph (0.8 km/h)
Power SourceElectric