It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the aerial platform.
FAMILIARIZATION
• Test Driving Speed
1. Depress and hold footswitch.
2. Raise “ ” main boom approximately
14 ft. (4 m) and then slowly move drive/
steer controller to full drive position.
Result: The maximum achievable drive
speed should be signicantly less than
stowed drive speed.
3. Lower boom to stowed position.
4. Extend “ ” y boom approximately
12 in. (30 cm) and then slowly move drive/
steer controller to full drive position.
Result: The maximum achievable drive
speed should be signicantly less than
stowed drive speed.
• Test Emergency Power
CAUTION
When operating on auxiliary power, do
not operate more than one function
at a time to avoid overloading 12-Volt
auxiliary pump motor. Do not use
emergency power unit continuously for
two minutes.
NOTE
To conserve battery power, test each
function through a partial cycle.
1. On platform control console, push in “ ”
emergency stop button to turn engine off.
2. Pull out “ ” emergency stop button.
3. Select “ ” on position from engine start/
on/off switch.
4. Depress and hold footswitch.
5. Turn “ ” emergency power switch to
“ ” on position and activate each function
control handle or switch.
Result: All boom and steer functions
should operate. Drive functions should
not operate.
NOTE
The emergency power unit has two-minute
duty cycle.
• Test Horn
1. Push “ ” horn pushbutton.
Result: Horn should sound.
Drive/Steer
Controller
Horn
Emergency Power
Switch
Emergency Stop
Engine Start/On/
Off Switch
Platform Leveling
Override Switch
Page 36
SJ 40T & SJ 45T
SJ 61T & SJ 66T
Function Tests Section 2 - Familiarization