SJ3220, SJ3226, SJ4720, SJ4726, SJ4732223198ABA
Section 5 – Procedures Skycoded Module
Menu Selection Sub-Menu Description
SETUPS
MACHINE
DEFAULTS
See 5.4-5 Initial Set-up and Change Defaults Procedure
MODEL
Factory set to congure machine type; conrm that the correct customer code is displayed. Determines the
initial default settings of all ADJUSTMENTS; Set to change to the correct model code for the machine.
CURVE Selects the proper preprogrammed load/height curve.
BATTERY Selects the type of battery installed in machine.
VEHICLE Selects the type of vehicle.
TILT SETUPS
See 5.4-7 Calibrate Level Procedure
CALIBRATE
LEVEL
Calibrates Control Module CM1 tilt to zero degrees X and Y.
TILT
SHUTDOWN
Determines if Control Module CM1 will prevent functions when machine is tilted:
NEVER – no functions prevented
LIFT&DRIVE – lifting and driving prevented (lowering still allowed)
LIFT – lifting prevented (lowering and driving still allowed)
DRIVE – driving prevented (lifting and lowering still allowed)
ELEV. TILT
SHUTDOWN
Determines if Control Module CM1 will prevent functions when machine is both tilted and elevated.
HEIGHT SETUPS
ELEVATION@ Determines the “elevation” point – the platform height at which the machine is considered to be elevated.
CALIBRATE
HEIGHT
Calibrates platform height from 0% to 100%.
MIN LIFT Determines the minimum time between each static measurement during load calibration.
SAMPLES@ Determines the time between samples during dynamic lifting load calibration.
TILT
CORRECTION
Congures how to correct machine tilt so that Control Module CM1 height measurement is correct.
SLOWDOWN
Determines whether to reduce lifting speed as platform height approaches MAX LIFT setting or not to make
sure there is no overshoot.
RED KNOB
Determines if machine was built with the “red knob” manual override in the Holding Valves for emergency
lowering.
ANTI
OVERRISE
Determines if the machine has optional KC Anti Overrising switches. 1=disable, 2=enable.
LOAD SETUPS
See 5.4-8 Calibrate Load Procedure
CALIBRATE LOAD
Calibrates platform load estimation from 0% to 100% height, at rated load and empty, as measured by the lift
cylinder pressure sensor.
RESET
OVERRIDE
Determines if the count for Override function can be reset to zero.
FAULTY LOAD Determines whether to prevent movement if load estimate is implausibly low (i.e. damaged pressure sensor).
DYNAMIC SCALE Determines sensitivity to stop at OVERLOAD @HEIGHT, if platform load estimate is close to trip point.
FINETUNEup Determines the percentage of ne tuning calculated during Calibration for UP movement.
FINETUNEdown Determines the percentage of ne tuning calculated during Calibration for DOWN movement.
OL COUNT HIDE or SHOW the count for Overload triggers made.(CE models only).
OL SWITCH HYST Determines the version of Overload switches (CE model only).
INTERLOCKS
TRIGGERonly
Determines whether or not to trigger an interlock when the trigger is closed with no other function select and
after what delay to do it in.
TRIGGERwait
Determines whether or not to trigger an interlock when a function is selected without the trigger being closed
and after what delay to do it in.
Skycoded Control Module Menu Table (Continued)
Items highlighted in grey requires access level 2.