SMA Solar Technology AG Parameter lists
Technical Description SI5048-TEN093630 145
138# Chp Meters
19.1.4 Charge Controller (140#)
141# SIC40 Total
142# SIC40 1
Number Name Description displayed
value
Description
01 ChpStt State of CHP plant Idle Off
Run Operation
Lock Locked after
operation
02 ChpPwrAt Power of the CHP plant
03 ChpRmgTm Remaining time of the CHP plant
(Minimum running time in hours,
minutes and seconds)
04 ChpStrRmgTm Remaining time of the power
request of the CHP plant
(Minimum running time in hours,
minutes and seconds)
Number Name Description
01 TotSicEgyCntIn Total energy of all Sunny Island Chargers in kWh
02 TotSicTyEgyCntIn Total daily yield of all Sunny Island Chargers in kWh
03 TotSicPvPwr Total PV power of all Sunny Island Chargers in W
04 TotSicBatCur Total battery current of all Sunny Island Chargers in A
Number Name Description
01 Sic1EgyCntIn Energy of the first Sunny Island Charger in kWh
02 Sic1TdyEgyCntIn Daily yield of the first Sunny Island Charger in kWh
03 Sic1PvPwr PV power of the first Sunny Island Charger in W
04 Sic1PvVtg PV voltage of the first Sunny Island Charger in V
05 Sic1BatVtg Battery voltage of the first Sunny Island Charger in V
06 Sic1BatCur Battery current of the first Sunny Island Charger in A
07 Sic1HsTmp Heatsink temperature of the first Sunny Island Charger in °C
08 Sic1SWVers Software version of the first Sunny Island Charger