Parameter lists SMA Solar Technology AG
166 SI5048-TB-TEN110340 Technical Description
235# Generator Start
20 GdAlSns AI sensitivity Low Low Normal
Medium Medium
Normal Normal
High High
Number Name Description Value Explanation Default
Value
01 GnAutoEna Generator autostart Off Disable On
On Enable
02 GnAutoStr Number of autostarts 3
03 GnSocTm1Str SOC limit for switching
on generator for time 1
40 %
04 GnSocTm1Stp SOC limit for switching
off generator for time 1
80 %
05 GnSocTm2Str SOC limit for switching
on generator for time 2
40 %
06 GnSocTm2Stp SOC limit for switching
off generator for time 2
80 %
07 GnTm1Str Time 1 for generator
request in hours,
minutes and seconds
Begin: Time 1,
End: Time 2
08 GnTm2Str Time 2 for generator
request in hours,
minutes and seconds
Begin: Time 2,
End: Time 1
09 GnPwrEna Generator request
based on power
Off Disable Off
On Enable
10 GnPwrStr Generator request
switch-on power limit
4 kW
11 GnPwrStp Generator request
switch-off power limit
2 kW
12 GnPwrAvgTm Average time for
powerrelated generator
start
60 sec