HRX-OM-Q026
Chapter 8 Documents
HRSH Series 8.1 Specifications
8-5
8.1.5 Option T High head temp
Table 8-5 Specifications of HRSH100/150/200/250-W-20-T
1
Model
HRSH100-W-
20-T
HRSH150-W-
20-T
HRSH200-W-
20-T
HRSH250-W-
20-T
Circulating
fluid
system
Pump
capacity
Rated flow rate (Outlet)
L/min
125 (0.5 MPa)
Maximum flow rate
L/min
180
Maximum lifting height
m
80
Settable pressure range
5
MPa
0.10.8
Minimum necessary flow rate
6
L/min
40
Electrical
system
Applicable earth
leakage breaker
7
Rated current
A
40
50
Sensitivity
current
mA
30
Rated operating current
3
A
26
30
34
Rated power consumption
kW (kVA)
6.6(9.0)
8.2(10.4)
8.9(11.8)
Weight (in the dry state)
kg
Approx. 202
Table 8-6 Specifications of HRSH100/150/200/250-W-40-T
2
Model
HRSH100-W-
40-T
HRSH150-W-
40-T
HRSH200-W-
40-T
HRSH250-W-
40-T
Circulating
fluid
system
Pump
capacity
Rated flow rate (Outlet)
L/min
125 (0.5 MPa)
Maximum flow rate
L/min
180
Maximum lifting height
m
80
Settable pressure range
5
MPa
0.10.8
Minimum necessary flow rate
6
L/min
40
Electrical
system
Applicable earth
leakage breaker
7
Rated current
A
30
Sensitivity
current
mA
30
Rated operating current
4
A
12
13
15
19
Rated power consumption
kW (kVA)
6.5(8.2)
7.5(9.1)
9.0(10.5)
11.9(13.3)
Weight (in the dry state)
kg
Approx. 202
1: Refer to “Table 8-3 Specifications of HRSH100/150/200/250-W-20-” for items not listed.
2: Refer to “Table 8-4 Specifications of HRSH100/150/200/250-W-40-” for items not listed.
3: (1) Facility water temperature: 32
o
C, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20
o
C,
(4) Load: Refer to the specified cooling capacity (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 200 VAC,
(7) Piping length: Minimum
4: (1) Facility water temperature: 32
o
C, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20
o
C,
(4) Load: Refer to the specified cooling capacity (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC,
(7) Piping length: Minimum
5: With pressure control function using an inverter. When the pressure control function is not being used, the pump power supply
frequency setting function can be used.
6: Required flow rate to maintain the cooling capacity. When the flow rate is lower than the rated flow, use a by-pass piping set.
7: To be prepared by the user.