GW2145 - GW1160 - GW4060 - GW4190
5.3 “SET“ PARAMETERS
Set on the display.
To access this item press the Start/Stop button.
The Set item contains a number of setting parameters.
User level operators can only display the parameters and cannot modify any “Set” parameters.
With set parameter
“-d=0”
With set
parameter
“-d=1”
Detergent pump P1 dispensing rate.
Setting in ml/litre, with maximum threshold of 10 ml/litre.
The default value of this parameter is 5ml/litre.
Maximum recommended quantity with Smeg detergents:
10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P2 dispensing rate.
Setting in ml/litre, with maximum threshold of 20 ml/litre.
The default value of this parameter is 3ml/litre.
Maximum recommended quantity with Smeg detergents:
10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P3 dispensing rate.
(not present on GW2145)
Setting in ml/litre, with maximum threshold of 20 ml/litre.
The default value of this parameter is 10ml/litre.
Maximum recommended quantity with Smeg detergents:
15ml/litre.
Increase and decrease with the Selection buttons.
Water hardness setting
Set the hardness in °f, in steps of 5. Range: 5-60°f. The
default setting is 40°f.
Warning: Make sure that the value is actually the same as
the hardness of the water used.
Automatic opening at end of cycle
The default setting on GW appliances is “On”, but
automatic door opening can be disabled by changing the
parameter to “OF”.
If the option is enabled, the device door is opened
automatically at the end of the cycle.
Printer language
English by default, the language can be chosen from the
various options available
Demineralised water
The use of demineralised water can be activated or
deactivated depending on whether or not the relative
connection has been made (Activated: dn, Deactivated: --)