Communication
LAN
Connected
RS485-1
SESlave
NC
RS485-2
Modbus
2 of 2
Cellular
N/A
Wi-Fi
NC
ZigBee
MPSlave
M not Found
For each communication option, one of the following statuses is displayed:
Connected: The inverter established a successful connection and
communication with the specified server port
NC: Not Connected. Refer to
Troubleshooting Communication
on page 64
S_OK: The connection to the monitoring platform is successful (should appear
only if the inverter is connected to the server)
N/A : Not Applicable
x of y: Number of devices connected out of all devices
Temporarily displayed (with a clock sign):
Initializing communication
Connecting to a network
Connecting to SolarEdge servers
Error message (with the sign). Refer to
Troubleshooting Communication
on
page 64.
Inverter Energy Status
Displays the total energy produced during the last day, month, year and since inverter
installation.
-Three Phase System Installation Guide MAN-01-00505-1.2
44 Viewing System Status