10
Product Overview
DIP Switch
A DIP Switch is actually a set of small manual electronic switches that are designed to be
packaged with other circuits. It is currently equipped with the battery module.
The location of the DIP switch and the factory defaults are shown as below.
Figure 2-6 DIP Switch
ON
OFF
Default Configuration
1 2 3 4 5
A reserved function
Terminal resistance
Figure 2-7 Default configuration
NOTICE!
In the case of one tower, there is only one master battery module (always the
uppermost battery module). While the master battery module connects to the
inverter, please confirm that the DIP switch 5 must stay in the ON position, as well
as the DIP switch 5 on the rest of the battery modules in the ON positions. Usually,
the DIP switch 5 will be slid to the ON position in the factory settings.
In the case of more than two towers, except that the master battery module (always
the uppermost battery module) of the last tower shall be slid to the ON position,
the Dip switch 5 on the rest of the master battery modules shall be flipped up to the
OFF positions. Regarding the Dip switch 5 on the rest of the battery modules, please
confirm that they are in the ON positions. Usually, the DIP switch 5 will be slid to the
ON position in the factory settings.
To adjust the DIP switch, a small flat-head screwdriver should be prepared by the
users themselves. Do not use a pencil. Graphite from the pencil is conductive and
may damage the DIP switch.