26
200 COLOR TEMP ADJ menu: Select STD, COL1, COL2, or CH SET. ÷ 201
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D65).
COL2: Use common data (factory setting: D93).
CH SET: Use data for each individual channel (factory setting: D65). Use the numeric keypad to select the
desired channel.
201 COLOR TEMP ADJ (STD/COL1/COL2/xxCH): Select the adjustment method.
MANUAL...: Set with the MANUAL knob. ÷ 210
PROBE...: Set using a probe. ÷ 220
COPY...: Copy data from elsewhere. ÷ 260
RESTORE FACTORY SET: Return values to their factory settings.
TRIM...: Perform fine adjustments after setting the color temperature. ÷ 280
210 MANUAL (STD/COL1/COL2/xxCH): Set the following data necessary to perform knob
adjustment and select ADJUST.
ORIGINAL VALUE...: Set the initial value. ÷ 211
SIGNAL: Select the white signal to be used for adjustment.
INT: Use an internal signal. Simultaneously with the adjustment of the gain and bias, the 100
IRE and 20 IRE signals are automatically switched.
EXT: Use an external input signal. When adjusting the gain and bias, input the proper signal.
ADJUST...: Perform the adjustment with following knobs. ÷ 212
RED: CONTRAST knob (Adjust the R gain or bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or bias with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance with the PHASE knob.)
211 ORIGINAL VALUE: Select STD, COL1, COL2, or CH SET. ÷ 210
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D65).
COL2: Use common data (factory setting: D93).
212 ADJUST (STD/COL1/COL2/xxCH) (1/2): Adjust the gain with the proper knob.
GAIN R:xxxx G:xxxx B:xxxx
212 ADJUST (STD/COL1/COL2/xxCH) (2/2): Adjust the bias with the proper knob.
BIAS R:xxxx G:xxxx B:xxxx
Adjusting the Color Temperature — COLOR TEMP ADJ Menu