28
263 OTHER MONITOR (STD/COL1/COL2/xxCH): Input the address of the monitor
from which the data will be copied.
MONITOR ADDRESS: Input the address of the monitor from which the data will be
copied. ÷ 264
264 OTHER MONITOR (STD/COL1/COL2/xxCH): Select STD, COL1,COL2,
or CH SET. ÷ Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D65).
COL2: Copy common data (factory setting: D93).
CH SET: Copy data from a particular channel (factory setting: D65). Enter the
number of the channel from which the data will be copied.
When the input channel number is deleted with the Del button. the number “1”
appears instead. Restore the previous setting by pressing the MENU button, then re-
enter the channel number. (Setting with the UP/DOWN buttons or PHASE knob is
possible without pressing the MENU button.)
266 MEMORY CARD (STD/COL1/COL2/xxCH): Select the file name. ÷ 267
267 FILE NAME (STD/COL1/COL2/xxCH): Select STD, COL1, COL2,or CH
SET. ÷ Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D65).
COL2: Copy common data (factory setting: D93).
CH SET: Copy data from a particular channel (factory setting: D65). Enter the
number of the channel from which the data will be copied.
When the input channel number is deleted with the Del button. the number “1”
appears instead. Restore the previous setting by pressing the MENU button, then re-
enter the channel number. (Setting with the UP/DOWN buttons or PHASE knob is
possible without pressing the MENU button.)
280 TRIM (STD/COL1/COL2/xxCH): After setting the necessary items, select
ADJUST.
APPLY/NOT APPLY: Select whether to add the fine adjustment to the original setting
(APPLY) or not (NOT APPLY)
SIGNAL: Select the white signal to be used for adjustment.
INT: Use an internal signal. Simultaneously with the adjustment of the gain and bias,
the 100 IRE and 20 IRE signals are automatically switched.
EXT: Use an external input signal. When adjusting the gain and bias, input the proper
signal.
ADJUST...: Perform the adjustment with following knobs: ÷ 282
RED: CONTRAST knob (Adjust the R gain or bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or bias with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance with the PHASE knob.)
Adjusting the Color Temperature — COLOR TEMP ADJ Menu