52
750 EXTEND MENU: Choose the function to execute with the UP and DOWN buttons or PHASE
knob.
RE-LOAD FACTORY DATA...: Restore factory default data for the board installed in the
selected slot. ÷ 760
MEMORY CARD...: Read and write setting and adjustment data by using the monitor memory
card. ÷ 770
RE-START MONITOR: Restart the monitor. ÷ 780
ADJ INT SIGNAL SETUP: Automatically adjust the SETUP level and 100 IRE level of internal
signals. ÷ 790
760 RE-LOAD FACTORY DATA menu: Select a slot where a board is installed to
reload factory default data to the board.
SLOT1 CONTROL
SLOT2 EMPTY
SLOT3 EMPTY
SLOT4 EMPTY
SLOT5 EMPTY
SLOT6 VIDEO AMP
SLOT7 DEFLECTION
SLOT8 EMPTY
SLOT9 POWER SUPPLY
761 MEMORY CARD menu: Confirm the data reload operation.
DATA RESET TO
ITS FACTORY SETTING
AND MONITOR WILL RESTART
ARE YOU SURE?
OK: ENTER KEY
CANCEL: MENU KEY
To continue, press the ENTER button. ÷ Reset the data and automatically turn the monitor
off and on again.
To cancel, press the MENU button. ÷ Return to the RE-LOAD FACTORY DATA menu.
(760)
770 MEMORY CARD menu: Insert the monitor memory card into the MEMORY CARD slot and
select the operation to perform.
BACK UP SYSTEM DATA...: Write the data to the monitor memory card. ÷ 771
RE-STORE SYSTEM DATA...: Read the data from the monitor memory card. ÷ 772
Using Extended Functions — EXTEND MENU