<LENS1>
M06
F NO. DISP CONTROL
, RETURN Selects the iris indication on the panel when AUTO
IRIS is off:
CONTROL: Displays the value from the camera.
RETURN: Displays the value returned from the lens.
(When AUTO IRIS is on, the value returned from the
lens is always displayed.)
AF DISPLAY ON, OFF
ALAC AUTO, OFF With AUTO selected, the status is displayed at the
right.
(ACTIVE): Compensation is in progress.
(WAIT): Waiting for completion of lens initialization.
(STOP): Compensation is turned off for a non-
applicable lens.
F DROP COMP OFF
, ON, (OFF) Turns F drop compensation on/off.
During compensation, the compensation gain is
displayed on the right.
(OFF): For when a serial lens is not attached.
MAX GAIN 0.0
to 24.0 dB Maximum compensation value
DROP POINT 0 to 99, 50
Compensation start point
ROUNDNESS 0.0
to 12.0 dB Roundness of the compensation curve.
STORE LENS FILE Execute using ENTER. Saves settings to a lens file.
ARIA AUTO, OFF
With AUTO selected, the status is displayed at the
right.
(ACTIVE): Compensation is in progress.
(WAIT): Waiting for completion of lens initialization.
(STOP): Compensation is turned off for a non-
applicable lens.
GAIN LIMIT 0 to 12 dB, OFF
<LENS2>
M07
REMOTE CONTROL OFF, ON, (OFF)
Lens remote control from MSU/RCP on/off setting.
Same function as the Active button on the Zoom/
Focus Control screen of the MSU/RCP.
(OFF): When lens is not supported
CONTROL MODE ZOOM&FOCUS
, FOCUS,
FOLLOW FOCUS
ZOOM&FOCUS: Control ZOOM and FOCUS from an
MSU/RCP (control by lens demand is not
supported)
FOCUS: Control FOCUS from an MSU/RCP. ZOOM is
controlled by lens demand.
FOLLOW FOCUS: FOCUS is controlled by lens
demand, but can be adjusted (offset fine
adjustment) from an MSU/RCP. ZOOM is
controlled by lens demand.
Note
Settings other than FOLLOW FOCUS cannot be
modified when the offset is not 0 and REMOTE
CONTROL is OFF. To change settings, set REMOTE
CONTROL to ON.
FOLLOW FOCUS
OFFSET ADJUST SENS 1, 2, 3
, 4, 5 Sets the sensitivity of superimposing the offset of
the MSU.
OFFSET CANCEL GAIN 1, 2, 3
, 4, 5 Sets the sensitivity of canceling the offset on the
demand side.
<MIC GAIN>
M08
MIC1 20, 30, 40, 50, 60
dB Can be modified only in standalone operation.
MIC2 20, 30, 40, 50, 60
dB
MAINTENANCE
Page name
Page No.
Item Settings Description