EasyManua.ls Logo

Sony KLV-19T400A - AC Power Cord Wire Dressing (Non-CISPR); AC Power Cord Wire Dressing (CISPR)

Sony KLV-19T400A
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 14 –
KLV-19T400A,T400G,T400W
RM-GA013
4-1-13. AC Power Cord Wire Dressing
(Non-CISPR)
4-1-14. AC Power Cord Wire Dressing (CISPR)
1) Install AC cord holder to AC power cord at specified position as shown.
2) Then install the AC power cord with holder into AC cord bracket.
Non-CISPR model
Figure (a)
Non-CISPR
60 ± 5mm
AC power cord is above
Lead Assy, Earth
Install AC power cord with
holder into AC cord bracket
AC cord bracket
1) Install Ferrite Core to AC power cord at specified position as shown.
2) Next, install AC cord holder to AC power cord at specified position.
3) Insert AC power cord into slide, clamp to secure it in position.
4) Lastly, install the AC power cord with holder into AC cord bracket.
180 ±
80± 5mm
Install AC power cord with
holder into AC cord bracket
CISPR model
AC power cord is above
Lead Assy, Earth
Figure (b)
CAUTION:
1. Ensure that AC power cord is not stressed whilst inserting it into AC
cord bracket and slider, clamp (CISPR model).
Attach AC Power Cord into Slide, clamp