EasyManua.ls Logo

Sony RMT-D128A - Page 82

Sony RMT-D128A
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-9
4. Manual Adjustment
Manual Adjustment
1. TRK. Offset
2. Focus Gain
3. TRK. Gain
4. Focus Offset
5. Focus Balance
6. L.F. Offset
7. EQ BOOST
8. GD ADJ
Adjustment : Up/Down
Jitter 1D
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted manually. Select the
desired number [1] to [8] from the remote commander, and cur-
rent setting for the selected item will be displayed, then increase
or decrease numeric value with key or key. This value is
stored in the EEPROM. If CLV has been applied, the jitter is dis-
played for reference for the adjustment.
[1] TRK. Offset Adjusts tracking offset.
[2] Focus Gain Adjusts focus gain.
[3] TRK. Gain Adjusts track gain.
[4] Focus Offset Adjusts focus offset.
[5] Focus Balance Adjusts focus balance.
[6] L.F. Offset Adjusts loop filter offset.
[7] EQ BOOST
[8] GD ADJ
5. Auto Adjustment
Auto Adjustment
1. Auto TRK. Offset
2. Auto Focus Balance
3. Auto Focus Offset
4. Auto Focus Gain
5. Auto TRK. Gain
6. Auto EQ
7. Auto L.F. Offset
8. Auto Group Delay
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted automatically. Select the
desired number [1] to [8] from the remote commander, and se-
lected item is adjusted automatically.
[1] Auto TRK. Offset Adjusts tracking offset.
[2] Auto Focus Balance Adjusts focus balance.
[3] Auto Focus Offset Adjusts focus offset.
[4] Auto Focus Gain Adjusts focus gain.
[5] Auto TRK. Gain Adjusts track gain.
[6] Auto EQ
[7] Auto L.F. Offset Adjusts loop filter offset.
[8] Auto Group Delay
6. Memory Check
EEPROM DATA 1 -– DL -–
CD LCD SL L0 L1
Focus Gain xx xx xx xx xx
TRK. Gain xx xx xx xx xx
FCS Balance xx xx xx xx xx
Focus Bias xx xx xx xx xx
TRV. Offset xx xx xx xx xx
L.F. Offset xx xx xx xx xx
EQ Boost xx xx xx xx xx
Mirror Time xx -- xx xx
_
DOWN : Next Data
CLEAR: Default Set page. 1/2
EEPROM DATA 2 -– DL -–
CD LCD SL L0 L1
RF Jitter xx -- xx xx xx
RF Level xx -- xx -- --
FE Level xx -- xx -- --
FE Balance xx -- xx -- --
TRV. Level xx -- xx -- --
Analog FRSW xx xx xx xx xx
PLL Dac Gain xx xx xx xx xx
_
UP : Prev Data
CLEAR: Default Set page. 2/2
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR] key, but be careful that they are not recoverable after
initialization.
Before clearing the adjusted data, make a note of the set data. This
screen will also appear if [0] All is selected in the Drive Auto
Adjustment. In this case, default setting cannot be made.
For reference, the drive has been designed so that the gain center
value is 20 and offset value is 80. Other values will be in a range
of 10 to 80. If extreme value such as 00 or FF is set, adjustment
will be faulty. In such a case, check for disc scratch or cable dis-
connection, then perform adjustment again.

Table of Contents