1-27 (E)
VPL-EX100
2. Event Trace
The displayed items are described below.
TIMER
. Lamp Timer (Lamp 1): Time used of lamp 1
. Lamp Timer (Lamp 2): Time used of lamp 2
. Operation Timer: Operation time
LAMP TIMER RESET LOG
. OP Timer: Operation time
. Lamp Timer: Lamp time used just before reset
ERROR LOG
Displays the situation where an error occurs. Previous ten errors are displayed.
. OP Timer: Operation time during error occurrence
. Error
Error display Contents of error
LAMP FAILURE: Lamp error
FAN FAILURE: Fan error
COVER FAILURE: Cover error
TEMP FAILURE: Temperature error
TEMP WARNING: Temperature warning
NVM DATA ERRORNVM: Data error
LENS PROTECTOR FAILURE: Lens cover error
ANGLE FAILURE: Tilt error
ANGLE WARNING: Tilt warning
IRIS FAILURE: Iris error
IRIS WARNING: Iris warning
HIGHLAND WARNING: Highland mode warning
LOW RTC BATTERY: Insuffi cient remaining amount of battery
FILTER CRAMMED: Filter clogging
POWER SYSTEM FAILURE 1: Power error 1
POWER SYSTEM FAILURE 2: Power error 2
TEMP FAILURE: Temperature error
SYSTEM ERROR 2: System error
LAMP/FILTER REPLACE 15H: 15 hours before lamp/fi lter replacement
LAMP/FILTER REPLACE 50H: 50 hours before lamp/fi lter replacement
LAMP REPLACE: Lamp replacement
SIGNAL WARNING FREQUENCY OVER: Input signal frequency warning
SIGNAL WARNING SIGNAL SETTING MISTAKE: Input signal type warning
FILTER CLEANING: Filter cleaning
FILTER REPLACE: Filter replacement