2-11 (E)
VPL-EX100
2-5-3. Saving of DDC Data
1. Connect the AC plug and set this unit to standby state.
2. Double-click QuickAccess.exe to start the application.
3. Select a target model on the Model pull-down menu.
4. Select Save on the Load/Save pull-down menu.
5 Select DDC on the 3dgm/Lut pull-down menu.
6. Click the [Next] button.
7. Click the [Browse...] button.
The fi le selection window is displayed.
8. Set the destination fi le for the obtained data as below.
DDC data for INPUT A: ****_a_0_**
DDC data for INPUT B: ****_a_1_**
m
. For VPL-EX100, set INPUT A only.
. **** means model name, and ** means version.
9. Click the [Next] button.
10. Select the serial port used for connecting PC on the Serial Port pull-down menu.
Upper line: Serial port number used for connecting PC
Lower line: 38400 (not selectable)
11. Click the [Next] button.
The window displaying the model name of this unit, serial number, and the fi le path of the destination
of the obtained data to save is displayed.
12. Click the [OK] button.
The saving starts. Completed is displayed after completed.
13. Disconnect the AC plug.
14. Click the [Complete] button.