13.2.1: LIBRARY FILE SYSTEM
EDIT & LIBRARY > LIBRARY > FILE SYSTEM
Only elements that have a Category can be stored individually to the Library – For example, there is no Category for
the Input stage (gain, PAD etc) or the Aux send parts of the channel strip, so these parameters cannot be stored to the
Library other than as part of complete channel strips using the Input Channel Category.
The Misc Category is intended for storing combinations of channel or bus parameters. Currently, only a combination of
EQ and Dynamics can be stored in the Misc category, but this may be extended with a future software update.
The Library le system itself comprises a system of folders that reside on the console’s internal ash drive. The folder
structure is preset to comprise a top-level Library folder, within which are sub-folders called Categories, corresponding
to the various types of functions that can be stored in the Library (EQ, Dynamics, Channels, and so on). Within each
Category, the actual Library settings are stored - these are called Entries. This structure and the names of the folders
are xed and cannot be modied.