The unit starts the self-leveling when the temperature check has been completed indicated by
the flashing beam and flashing vial symbol at the display.
The unit is leveled when the laser beam is no longer flashing
(once every second).
If the laser is positioned beyond its self-leveling range of -12% to + 40%,
the laser beam remains flashing.
Note: If the laser can’t level during two minutes, the error message 141 “Time Out” appears.
Reposition the laser within its self-leveling range.
The lasers cross axis is completely compensated over the entire roll range.