XT6600/6800
47
1. After pressing START, it stops and shows E1 after the motor runs for a
few seconds.
Method 1 Check if the switch connector (CNT6) is plugged in.If not,
plug it in.
Method 2 Adjust the switch sensor position paorallel to the roller.
Method 3 If either of the said methods do not solv the problem, please
change the driving board.
2.After pressing START, the motor is still running but it shows E1 after a
few seconds.
Method 1 Check it the motor connector (M+,M-) is plugged in. If not,
just plug it in.
Method 2 Take off the motor connector(M+,M-) and test the motor
resistance with the electronic meter. If the loop is off, please
change the motor.
Method 3 Adjust the speed half-resistance to the adequate torque.
Method 4 If none of any said methods work, please change driving
board.
3.When the power turns on, it shows E7
Method 1 Check if the switch connector of the lift motor
(CNT4) is plugged in. If not plug it in.
Method 2 Take off the connector of the lift motor (CNT4) and
test the motor resistance with the electronic meter.
If the loop is off, please change the lift motor.
Method 3 If none of the said methods work, please change
lift motor.
4.After pressing INCLINE for 3 to 5 seconds, it remains still and shows E5
Method 1 Check if the connector of the lift motor (CNT9) is
plugged in. If not, just plug it in.