Method 2 Tade off the connector of the lift motor (CNT4) and test the
motor resistance with the electronic meter. If the loop is off,
please change the lift motor.
Method 3 If none of the said methods work, please change driving board.
5.Key shown in the monitor
Method 1 Check if the safety key is plugged in. If not, plug it in.
Method 2 Check if the satety connector (CNT 1) is plugged in. If not,
plug it in.
Method 3 Take off the safety connector (CNT 1)and test the motor
resistanc with the electronic meter. If the loop is off, please
change the micro-switch.
6.E5 shown in the monitor
Method 1 If there are some problems with the speed .
Step 1 Take off the safety KEY and press INCLINE-.SPEED+
at the same time.After a few seconds, if will show SPD.
Step 2 Thwn plug in the KEY and press start. It will show 0.5
(0.8kph).
Step 3 Adjust the SPEED half-resistance till it shows 0.5
(0.8kph) in the left window.
Step 4 Press the button SPEED and the motor will stop after
the speed torque goes up to 10 (16kph) for a few
seconds. Then turn on the power.