Steris SYSTEM 1E - Troubleshooting; Section Description Page

Steris SYSTEM 1E
179 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-1
764333-675
5.1. Liquid Chemical Sterilization Processing Cycle Faults........................................................5-3
5.1.1. Wait For UV ................................................................................................................................... 5-3
5.1.2. Temperature Under 43°C............................................................................................................... 5-3
5.1.3. UV Intensity Timeout...................................................................................................................... 5-3
5.1.4. Fill Problem.................................................................................................................................... 5-4
5.1.5. Heat Problem................................................................................................................................. 5-4
5.1.6. Temperature Under 45.5°C............................................................................................................ 5-4
5.1.7. Concentration Low......................................................................................................................... 5-5
5.1.8. Chamber Level Low....................................................................................................................... 5-5
5.1.9. Heater Problem.............................................................................................................................. 5-5
5.1.10. Chamber Open ............................................................................................................................ 5-5
5.1.11. Temperature Over 60°C............................................................................................................... 5-6
5.1.12. UV Lamp Problem........................................................................................................................ 5-6
5.1.13. MaxPure™ Filter Test Failed (a. without and b. with numbers)................................................... 5-6
5.1.14. Temperature Problem.................................................................................................................. 5-6
5.1.15. Power Failure............................................................................................................................... 5-7
5.1.16. HP Pump Failure.......................................................................................................................... 5-8
5.2. Diagnostic Cycle Faults...........................................................................................................5-9
5.2.1. A/D Converter Fault ....................................................................................................................... 5-9
5.2.2. Inlet H2O Temp < 43°C.................................................................................................................. 5-9
5.2.3. UV Intensity Timeout...................................................................................................................... 5-9
5.2.4. UV Lamp Below 14.5 mA............................................................................................................... 5-9
5.2.5. Fill time > 5 Minutes..................................................................................................................... 5-10
5.2.6. Pressure Transducer Fault .......................................................................................................... 5-10
5.2.7. Circulation Pressure Low............................................................................................................. 5-10
5.2.8. Thermocouple Failed ................................................................................................................... 5-11
5.2.9. Circulation Valve Fault................................................................................................................. 5-11
5.2.10. Heat Rate Low ........................................................................................................................... 5-11
5.2.11. Drain Valve Fault ....................................................................................................................... 5-11
5.2.12. Drain Time Fault ........................................................................................................................ 5-11
5.2.13.Concentration Monitor Failed...................................................................................................... 5-12
5.2.13. Concentration Monitor Failed (cont.).......................................................................................... 5-13
5.2.14. MaxPure Filter Membrane Fault (a. without numbers and b. with numbers) ............................. 5-13
5.2.15. Drain Check Fault ...................................................................................................................... 5-14
Section 5: Troubleshooting
Section Description Page

Table of Contents