Servicing work every 1000 hours
On-board charger (if present): check that it is operating correctly
Truck cables and connectors: check the condition and position
Electrical components: clean
Test the insulation between the chassis and the electric motors
Test the insulation between the chassis and the electronic control
On-board charger (if present): earthing and isolation circuit tests
Hydraulic system
Pump unit: check the general condition
Pump unit: check the wear of the lifting motor brushes
Hydraulic system: check the oil level
Hydraulic system: check for any leakage from cylinders and hydraulic fittings
Hydraulic system: check the condition of the pipe lines
Load lift system
Mast: check that it is in good condition
Mast: lubricate the sliding tracks of the mast profiles
Mast: check that it is correctly mounted
Lift cylinders, chains, rollers and end stops: check the condition, mounting and operation
Lifting chain: check chain adjustment and maintenance
(clean, adjust, grease)
Fork holder: check that the fork holder is in good condition, is correctly mounted and is operating
correctly
Protective device: check that the anti-shearing protective guard is in place, is in good condition
and is correctly mounted
Mobile chassis: check that the fork holder is in good condition, is properly mounted and is oper-
ating correctly
Additional servicing work every 3000 hours
Hydraulic system
Replace the hydraulic oil and the hydraulic oil filter
Load lift system
Lift mast maintenance: check the lateral and axial clearance of the bearings
Additional servicing work every 6000 hours
Transmission
Replace the reduction gear unit oil