2 Electrical data of the machine
2.2 Electrical data
2-2
2.2 Electrical data
Valid for:
≥ Component type 003 CMS 822
CMS 933 CMS 830 C CMS 740 CMS 530 T CMS 520
CMS 922 CMS 822 CMS 730 S CMS 530
≥ Component type 002
CMS 730 T CMS 520 C
≥ Component type 000 CMS 420 E
(type 579)
Electrical data Values
Supply voltage 400 V ±10 %
50 or 60 Hz
No. of phases 3
Observe clock wise phase sequence
Rated current 7 A
Main fuse (of customer) 16 A slow-blow
each phase
Power consumption approx.. 2.6 kW
Tab. 2-2 Connection data of the knitting machine
Before connecting the machine, check the mains voltage available on site.
It is generally not admissible to connect electrical or electronical
components of other makes to the machine's internal wiring. If such
assemblies are used, we are unable to guarantee optimum functional
performance of the machine.
If the knitting machine is operated by means of a generator, make sure
that the voltage supplied by the generator meets the requirements of the
EN 60204-1, paragraph 4.3.1.
In case of queries, please call the STOLL Helpline.