928 Mixing Console
E 1/6 General
Edition: 07.02.01
Unweighted noise voltage, according to IEC 468-2 (DIN 45405)
Microphone Equivalent input noise for 23 kHz bandwidth,
termination 200 : < –126 dBu
Signal-to-noise ratio PPM version, relative to line level (+6 dBu)
VU version, relative to peak output level (+6 VU
+10 dBu)
On master output, master fader closed: > 95 dB
One channel, input and master faders at 0 dB mark, unity gain;
- Filters off: > 93 dB
- Filters on, linear: > 92 dB
11 channels, all faders at 0 dB mark, unity gain;
- Filters off: > 85 dB
- Filters on, linear: > 83 dB
Harmonic ratio PPM version, measured with line level +6 dBu;
VU version, measured with nominal output level 0 VU, or peak output
level +6 VU;
unity gain, 31.5 Hz...16 kHz: 70 dB
Crosstalk attenuation Channel to channel,
- without panorama potentiometer >80 dB
- with panorama potentiometer >70 dB
Channel bus selector switched off: >90 dB
Fader attenuation, input >100 dB
Fader attenuation, output >90 dB
Power supply 100...240 V, 50/60 Hz
Power consumption (Studer 928 32/8/4) approx. 400 VA
Note: Depending on the application, the on-air mixing consoles can have
different configurations. For this reason the abovementioned values
are applicable only to a typical configuration; in an individual case,
the values may differ.
We reserve the right to make changes as technological progress may
warrant.