1.0 INTRODUCTION AND SAFETY
1.0 INTRODUCTION AND SAFETY
1.1 General
The CeilAir
®
(OHS) ceiling mounted air conditioning unit documented in this manual is designed and
manufactured by STULZ Air Technology Systems, Inc.
CeilAir systems are constructed using the finest available materials/components, state-of-the-art
technology and quality craftsmanship. The unit will provide years of trouble free service if installed and
maintained in accordance with this manual. Damage to the unit from improper installation, operation, or
maintenance is not covered by the warranty. Due to advances in technology, components described herein
are subject to change without notice.
All CeilAir units and CyberAir centrifugal condensers are designed to be installed indoors, unless otherwise
noted on the equipment.
1.2 Product Description
CeilAir units are designed to be the most versatile and flexible ceiling-mounted air conditioning systems in
the industry. The unit is available in air-cooled, water-cooled, glycol-cooled, and chilled-water configurations.
The cooling capacity in Btu/h will depend on the unit size, which can range from 1 to 10 tons (3.535 kW),
and can be either a single stage or a dual stage unit.
In addition to cooling, other functional modes of operation include heating, humidification, dehumidification
and filtration to provide complete environmental control of a conditioned space. The cabinet configuration
is available in a 2 ft x 4 ft frame for units ranging from 12,000 to 40,000 Btu/h (spot cooler or ducted) or a
larger frame for units ranging from 48,000 to 120,000 Btu/h (ducted only). For ducted units, there are three
basic configurations of airflow patterns: 90º right angle, straight-through (standard), and same-face (see
Figure 9 in section 2.4.3.1). Refer to the installation drawing provided with the unit for the type of cabinet
configuration and for the layout dimensions.
1.3 Control Devices
STULZ offers a variety of control devices for CeilAir units. Control interfaces are typically remotely mounted
to a wall or control panel.
The default control device for CeilAir units is the ATech digital thermostat, which provides basic control of
the system. Slightly different wiring is used with the thermostat in single- and dual-stage units, as shown in
Figure 16 in sections 2.7.2.12.7.2.2. The single-stage version is the ATech 1.1. The two-stage version is
the ATech 1.2. An operating manual for the thermostat may be provided on request separately.