Sumitomo Z2C - Splice Protection

Sumitomo Z2C
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-27
2. Basic splicing operationDrop cable splicing
2. Basic splicing operation
Splice protection
Splice protection
1: Open the heat shrink oven lid. Open
the wind hood, and then open the lid of
both fiber coating clamps.
4: While keeping apply a slight tension
to the cable ends, close the heat
shrink oven lid.
Start the heat shrink process.
5: After the heat shrink process is
complete, open the heat shrink
oven lid and then take out the
cable.
3: While maintaining a slight tension on
the cable ends, transfer the cable to
the heat shrink oven and then lower
it.
2: Take out the cable and slide the fiber
protection sleeve onto the fiber. Make
sure that the protection sleeve is
centered over the splice and at least
5mm of the sleeve overlaps the cable
sheath at each end of the splice.
Drop cable
Fiber protection sleeve
At least 5mm of the sleeve must overlap the
cable sheath at each end of the splice.
Pay attention not to bend and
flex the cable. Failure to do so
can cause the splice to break.
When closing the lid, make
sure you apply a sligh
t
tension to the cable ends to
prevent the cable from
going slack.
Drop cable

Table of Contents