2-17
2.Basic splicing operation|Optical fiber splicing
2. Basic splicing operation
●
Starting the automatic splice
Here is a summary of the splicing operation procedures.
1: Slip a protection sleeve over the fiber.
2: Strip the fiber coating and clean the
fiber. If you have performed an arc test,
prepare the fiber again.
▸ P.2-11 Stripping the fiber coating
▸ P.2-12 Cleaving the fiber
3: Load a prepared fiber in the fiber coating clamp of the fusion splicer.
(▸P.2-14)
Tap the Set icon
()or press the Set key()to start splicing.
2: Inspection of fiber end face &
dust.
4: Estimated loss is displayed.
After the splicing
process is complete,
▸Checking splice image and data P.2-18
▸Splice error possible cause and troubleshooting P.2-19
▸Proof test P.2-20
■Makin
a splice
Be sure to slip the fiber
protection sleeve over one of
the fibers to be spliced before
stripping and cleaving the
fibers. The fiber protection
sleeve cannot be installed after
splicing.
1: Tap the Set icon ( ).
3: Arc is
enerated.