7-5
7. Other convenient functionsAuto startTripod fixing screws
7. Other convenient functions
Auto start heating
When fiber is placed into the heat shrink oven, the heater lid is automatically
closed, and then the heating operation is automatically started. No need to
press Heater key ( ) or touch Heater icon ( ).
The Z2C has Auto start function that automatically starts the splicing process and
the heating operation.
In a high location, secure the Z2C to a tripod with M8 screw or
1/4-20UNC screw on its bottom to prevent it from dropping.
Do not use a tripod with a thread length of >13mm (33/64"). Doing
so can risk damage the fusion splicer.
Tripod fixing screws
Screw hole for
M8 screw
Screw hole for
1/4-20UNC screw
Auto start
Caution
Auto start splicing
When fiber is inserted into the splicer and the hood is closed, the splicing
process is automatically started. No need to press Set key ( ) or touch Set
icon ( ).
The Z2C has screw holes for M8 screw and 1/4-20UNC screw on its bottom.