2 Product Introduction User Manual
6
2
3
4
5
61
7
8
Fig. 2-2 Inverter Appearance (SG5K-D for reference)
Item
Name
Description
1 PV terminals
Positive and negative DC input connectors.
One or two or three pairs, depending on inverter
type.
2
DC switch (optional)
To disconnect the DC current safely.
3 RS485 terminal
To connect the communication module, such as
Wi-Fi module.
4
Meter | DRM
terminal
Connections to the energy meter and external
Demand Response Enabling Device (DRED).
5
Second PE terminal
For reliable grounding.
6
AC terminal
To feed power into the utility grid.
7 LCD panel
The display and two buttons can be used to
access current operating data or change inverter
settings.
8 Mounting rack
For mounting the inverter to the wall mounting
bracket.
Dimensions and Weight
W
D
H
Fig. 2-3 Dimensions of the Inverter