User Manual 2 Product Introduction
5
Item
Description
Remarks
C
Sungrow single-phase
or three-phase meter
(optional)
Measures the export power and communicates
with the inverter via an RS485 connection.
D
Utility grid
Grid earthing system types: TT, TN.
E
Household load
Devices that consume energy.
For the TT utility grid, the N line voltage to ground must be 30 V or less.
2.2 Inverter
Type Description
The type description is as follows (take SG3K-S as an example):
SG 3K S
-
S: single MPPT, D: dual MPPTs
Code of power level
Code of PV grid-connected inverter
Tab. 2-1 Power Level Description
Appearance
The image shown here is for reference only. The actual product you receive
may differ.
Type
Nominal Output Power
Nominal Grid Voltage
SG2K-S
2000 W
230 Vac (single phase)
SG2K5-S 2500 W
SG3K-S 3000 W
SG3K-D 3000 W
SG5K-D 4990 W
SG8K-D 8000 W