User Manual 2 Product Introduction
9
Inverter provides various parameter configurations for optimal operation. You
can set the country via the iSolarCloud App or the cloud server, in case you
require further, please contact Sungrow.
Communication interface
You can choose the RS485 terminal for connecting a communication module
to the PV system, such as Wi-Fi module.
communication failure or other unexpected damage.
Further information on the communication module can be found in
the respective Quick Installation Guide.
Earth fault alarm
If an earth fault occurs, the error code will be displayed on the LCD screen.
The buzzer inside the inverter will beep to signal an external alarm.
Protective function
The protective functions are integrated in the inverter, including short circuit
protection, grounding insulation resistance surveillance, residual current
protection, anti-islanding protection, DC overvoltage / over-current protection,
etc.
2.4.2 External Demand Response
The inverter provides a RJ45 port for connecting to a demand response
enabling device (DRED). The DRED asserts demand respond modes (DRMs).
The inverter detects and initiates a response to the supported demand
response commands within 2 s. The following table lists the DRMs supported
by the inverter.
Tab. 2-3 Demand Response Modes (DRMs)
The export power to the grid is 100% of the rated power, but subject
to the constraints from other active DRMs.