EasyManua.ls Logo

Sungrow SG8K-D - Page 75

Sungrow SG8K-D
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual 10 Appendix
67
Parameters
SG3K-D
SG5K-D
SG8K-D
Leakage current protection
Yes
Low voltage fault ride through
(LVFRT)
No No Yes
Anti-islanding protection
Yes (frequency shift)
DC switch
Optional
Overvoltage category
III [AC], II [DC]
Overvoltage protection II [AC] II [AC]
II [AC], II
[DC]
Safety protection class
I
System Data
Max. efficiency
98.4 %
98.4 %
98.5 %
Max. European efficiency
97.7 %
98.0 %
98.0 %
Isolation method
Transformerless
Ingress protection rating
IP65
Pollution degree outside/inside
the enclosure
3 / 2
Power loss in night mode
< 1 W
Operating ambient
temperature
-25 to +60
Allowable relative humidity
0–100 % (non-condensing)
Cooling method
Natural cooling
Max. operating Altitude
4000 m (derating when > 2000 m)
Display
Graphic LCD
Communication
Wi-Fi
PV connection type
MC4
AC connection type
Plug and play connector
Certification
IEC 62109-1, IEC 62109-2, IEC 62116, IEC
61727, EN 61000-6-2, EN 61000-6-3,
AS4777.2, ABNT NBR 16149, ABNT NBR
16150, VDE-AR-N-4105, CEI 0-21,
VDE0126-1-1, UTE C15-712, VFR-2014,
EN50438, C10/11, G83/2, G59/3
Mechanical Data
Dimensions (W x H x D) 360 mm x 390 mm x 133 mm
360 mm x
390 mm x
148 mm
Mounting method
Wall-mounting bracket
Weight
11.5 kg
15.5 kg

Table of Contents

Related product manuals