57
6.4.6 Speed Calibration (SPEd)
Keep the belt weigher running at a constant speed. After the belt running time of a revolution being
measured by stopwatch, do this operation for correcting Speed Coefficient.
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
Main Display Interface
MENU+】【 : F2-CAL
ENT+】【 : --SPEd--
ENT
ENT
M
Input Belt Length [m]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
P: Pulse Count; tI: Run-timer [s]
MENU: Exit ENT: Save
M
Run-Timer over
ENT
Input Running Time of a Revolution [s]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
】【 :
Display Speed Coefficient [C=] or
Pulse Count [P=]
[P103]: Speed Coefficient [pulse/m]