EasyManua.ls Logo

Supmeter BST100-B11 - Speed Calibration (Sped)

Supmeter BST100-B11
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
6.4.6 Speed Calibration (SPEd)
Keep the belt weigher running at a constant speed. After the belt running time of a revolution being
measured by stopwatch, do this operation for correcting Speed Coefficient.
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
Main Display Interface
MENU+】【 : F2-CAL
ENT+】【 : --SPEd--
ENT
ENT
M
Input Belt Length [m]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
P: Pulse Count; tI: Run-timer [s]
MENU: Exit ENT: Save
M
Run-Timer over
ENT
Input Running Time of a Revolution [s]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
】【 :
Display Speed Coefficient [C=] or
Pulse Count [P=]
[P103]: Speed Coefficient [pulse/m]
www.zemicusa.info

Table of Contents

Related product manuals