6.4.6 Speed Calibration (SPEd)
Keep the belt weigher running at a constant speed. After the belt running time of a revolution being
measured by stopwatch, do this operation for correcting Speed Coefficient.
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
Main Display Interface
【MENU】+【▲】【 ▼】: ≡F2-CAL≡
【ENT】+【▲】【 ▼】: --SPEd--
【ENT】
【ENT】
M
Input Belt Length [m]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
P: Pulse Count; tI: Run-timer [s]
【MENU】: Exit 【ENT】: Save
M
Run-Timer over
【ENT】
Input Running Time of a Revolution [s]
RUN
AUTO
EXT
ALARM
kg
t
t/h
kg/m
【▲】【 ▼】:
Display Speed Coefficient [C=] or
Pulse Count [P=]
[P103]: Speed Coefficient [pulse/m]
www.zemicusa.info