36
6.3 F1-SET Setting
6.3.1 Basic Scale Parameters (SCAL)
No.
Sign
Parameter
Range
Default
Set
P100
UnIt
Weight Display Unit
0: kg
1: t
([P107] Scale Unit = kg)
0
0: g
1: kg
([P107] Scale Unit = g)
P101
-dot
Weight Decimal Point
0: o
1: o.o
2: o.oo
When [P100]=1, its valid.
1
P102
--L-
Belt Length
0.01~5000.00m
10.00[*]
P103
--C-
Speed Coefficient
1.0~99999.9 pulse/m
100.0[*]
P104
ZEro
Zero Value
0~60000 (Max. AD Value)
15000[*]
P105
CALC
Span Coefficient
1~99999999
200000
[*]
P106
dEAd
Weighing Deadband
±(0.00~200.00) t/h
([P107] Scale Unit = kg)
If Flow < Deadband value, the variance of
Totalized Weight will be ignored.
±0.00
±(0.00~200.00) kg/h
([P107] Scale Unit = g)
P107
SCAL
Internal Scale Unit
0: kg
1: g
0/1[*]
* „RAM Reset operation has no effect on this parameter.