AMI Codes-II
Program List and Explanations
A-96.250.571 / 050517 81
5 Installation
5.1 Sensors
5.1.1 Disinf: Select the disinfectant in use. Available disinfectants are:
Free chlorine
Hypochl. acid
Ozone
Chlorine dioxide
Bromine
Iodine
Monochloramine
5.1.2 Dimension: The measuring value can be displayed as ppm or mg/l
5.1.3 Interpolation:
Yes: Display and output of free chlorine value changes linearly
between two measuring points. Select this mode if you encounter
problems with the controller of free chlorine.
no: Step response of display and output between two measuring
points.
5.1.4 Ref. Verification: Set absorbance value of verification kit according
to label.
Range: 0.200–0.600
5.1.5 Standards: Program the two standard solutions for the calibration
of the pH electrode. If pH electrode is not connected the
programmed standards are not active.
Range: 1.00 pH–13.00 pH
5.1.6 Cleaning: Program if one or two solutions are used on Cleaning
module. See 3.5 Cleaning, p. 79
Range: 1 Solution, 2 Solutions