AMI INSPECTOR pH
Default Values
A-96.250.761 / 161017 69
11. Default Values
Operation:
Sensors: Filter Time Const.: .................................................................30 Sec
Hold after Cal.:.....................................................................300 Sec
Alarm Relay ...................................................................... same as in Installation
Relay 1 / 2 ...................................................................... same as in Installation
Input ...................................................................... same as in Installation
Logger: Logger Interval:.............................................................. 30 Minutes
Clear Logger:................................................................................ no
Installation:
Sensors Flow: Flow measurement: ....................................................... None
Parameter: Type of sensor: .............................. as set, pH or Redox
Parameter: Sensor Check: .......................................................... Off
Temp. Sensor: ............................................................................. No
Default Temp. ..........................................................................25 °C
Temp. Compensation............................................................. Nernst
Standards: Standard 1............see Chap. 4 Set Buffer Values, S. 24
Standards: Standard 2............see Chap. 4 Set Buffer Values, S. 24
Standards: Redox Standard .................................................475 mV
Quality Assurance.................................................................... 0: Off
Signal Output Parameter:.................................................................... Meas. Value
Current loop:................................................................. 0/420 mA
Function:.................................................................................. linear
Scaling: Range low:................................................... 0.00 pH/0 mV
Scaling: Range high: ......................................... 14.00 pH/1000 mV
Alarm Relay: Alarm:
Alarm high: ........................................................ 15.00 pH/1500 mV
Alarm low:............................................................ -3.00 pH/-500 mV
Hysteresis:........................................................................... 0.10 pH
Delay: ......................................................................................5 Sec
Sample Temp:
Alarm High:.............................................................................. 55 °C
Alarm Low:................................................................................. 5 °C
Case temp. high: ..................................................................... 65 °C
Case temp. low:......................................................................... 0 °C