10. Alternator / Starting Clutch
10-2
Operational Precautions
General information
y Refer to chapter 5: Engine removal and installation
y Refer to chapter 1 : The troubleshooting and inspection of alternator
y Refer to chapter 16: The service procedures and precaution items of starter motor
Specification Unit: mm
Item Service Limit
ID of starting driven gear 32.060
OD of clutch cover 27.940
Torque value:
Flywheel nut 5.0~6.0kgf-m
Pipe bolt 8mm 1.5~2.0kgf-m
Oil screen cover 1.3~1.7kgf-m
Starting clutch hex mounting nut 9.0~10.0kgf-m with oil on the thread
Starting clutch hex socket bolt 1.0~1.4kgf-m with adhesive
Special service tools
Flywheel puller SYM-3110A01
Universal fixture SYM-2210100
Anti-loosen mounting nut socket of starter gear SYM-A12590201