13. Cooling System
13-5
Removing the reserve tank filler cap.
Check the liquid level in the reservoir. Add
coolant to proper level if too low.
Reinstall the reserve tank filler cap.
Radiator
Removal
Remove the front guard, check for any leakage
from weld seam.
Blow cooling fan clean using compressed air. If
the cooling fan is blocked by dirt, use low
pressure water jet to clean it.
Care shall be taken when straightening the sink
fan.
Coolant leakage
Loosen 2 nuts and 4 screws.
Remove the front mudguard by pulling it
forward.
Cooling fan
cou
p
le
r
Thermostat
coupler
Reserve tank filler cap